Mosa GE 8 YSXC
Generator Diesel YANMAR 3TNV80 – Single-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By single-phase power: 8 kVA (7.2 kW)/ 230V / 34.8A
- PRP single-phase power: 7.5 kVA(6.7 kW)/ 230V /32.6A
- Frequency: 50 Hz
-
Mosa GE 10 YSXC
Generator Diesel YANMAR 3TNV80 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS- Stand-By three-phase power: 9.5 kVA (7.6 kW) / 400V / 13.7A
- PRP three-phase power: 9 kVA (7.2 kW) /400V / 13A
- PRP single-phase power: 4.5 kVA / 230V / 19.5A
- Frequency: 50 Hz
-
Mosa GE 10 YSX
Generator Diesel YANMAR 3TNV80 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS- Stand-By three-phase power: 9.5 kVA (7.6 kW) / 400V / 13.7A
- PRP three-phase power: 9 kVA (7.2 kW) /400V / 13A
- PRP single-phase power: 4.5 kVA / 230V / 19.5A
- Frequency: 50 Hz
-
Mosa GE 15 PSX
Generator Diesel PERKINS 403A-15G1 – Three-phase synchronous alternator – Three-phase power 14 kVA (11.2 kW) – Single-phase power 6.5 kVA – Water Cooled
MOSA model GE 15 PSX is a super silenced diesel generating set. The machine construction incorporates an integral roll bar, central lifting point, forklift pockets and rear canopy section that is hinged to provide full access to the engine for maintenance. The 60 litre fuel tank provides a running time of 21.5 hours. At 580kg the machine is compact and easily transportable using the optional site tow or road tow trailer.
The recessed control panel is lockable and houses the sockets and machine controls including ELCB-GFI, circuit breaker and engine protection device.
When the Compound System is combined with a double control AVR the Compound System overrides the AVR when a heavy load is applied and also provides a backup voltage regulation in the event of AVR failure.
EAS models are pre-wired to accept the optional MOSA EAS Automatic Start-Up Panel which plugs into the front panel of the Generator and enables the machine to be used as an emergency standby power unit in the event of power failure from the mains supply.
Also available is an optional TCM remote control allowing start/stop of the engine up to 10 metres distance from the machine.
Suitable for a wide range of uses including industrial sites, residential, construction, noise sensitive environments and emergency standby power.
In according with CE regulation
-
Mosa GE 15 YSXC
Generator Diesel YANMAR 3TNV88 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 15 kVA (12 kW) / 400V / 21.6 A
- PRP three-phase power: 14 kVA (11.2 kW) / 400V / 20.2 A
- PRP single-phase power: 6.5 kVA / 230V / 28.3A
- Frequency: 50 Hz
-
Mosa GE 15 YSX
Generator Diesel YANMAR 3TNV88 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 15 kVA (12 kW) / 400V / 21.6 A
- PRP three-phase power: 14 kVA (11.2 kW) / 400V / 20.2 A
- PRP single-phase power: 6.5 kVA / 230V / 28.3A
- Frequency: 50 Hz
-
Mosa GE 20 PSX
Generator Diesel PERKINS 404A-22G1 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 22 kVA (17.6 kW) / 400V / 31.8 A
- PRP three-phase power: 20 kVA (16 kW) / 400V / 28.9 A
- PRP single-phase power: 67 kVA / 230V / 30.4A
- Frequency: 50 Hz
-
Mosa GE 20 YSXC
Generator Diesel YANMAR 4TNV88 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS- Stand-By three-phase power: 20 kVA (16 kW) / 400V / 28.9 A
- PRP three-phase power: 18 kVA (14.4 kW) / 400V / 26 A
- PRP single-phase power: 67 kVA / 230V / 30.4A
- Frequency: 50 Hz
-
Mosa GE 20 YSX
Generator Diesel YANMAR 4TNV88 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS THREE-PHASE
- Stand-By three-phase power: 20 kVA (16 kW) / 400V / 28.9 A
- PRP three-phase power: 18 kVA (14.4 kW) / 400V / 26 A
- PRP single-phase power: 7 kVA / 230V / 30.4A
- Frequency: 50 Hz
POWER RATINGS SINGLE-PHASE
- Stand-By single-phase power: 20 kVA (16 kW) / 230V – 115V / 86.9 A – 173.9A
- PRP single-phase power: 18 kVA (14.4 kW) / 230V – 115V / 78.3 A – 156.5A
- Frequency: 50 Hz
-
Mosa GE 35 PSX
Generator Diesel PERKINS 1103A – 33G – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 33 kVA (26.4 kW) / 400 V / 47.6 A
- PRP three-phase power: 30 kVA (24 kW) / 400 V / 43.3 A
- PRP single-phase power: 11 kVA / 230 V / 47.6 A
- Frequency: 50 Hz
-
Mosa GE 35 PS SX
Generator Diesel PERKINS 1103A – 33G – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 33 kVA (26.4 kW) / 400 V / 47.6 A
- PRP three-phase power: 30 kVA (24 kW) / 400 V / 43.3 A
- PRP single-phase power: 11 kVA / 230 V / 47.6 A
- Frequency: 50 Hz
-
Mosa GE 35 YSC
Diesel generating set YANMAR 4TNV98 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 33 kVA (26.4 kW) / 400V / 47.6 A
- PRP three-phase power: 30 kVA (24 kW) / 400V / 43.3 A
- PRP single-phase power: 11 kVA / 230V / 47.8 A
- Frequency: 50 Hz
-
Mosa GE 35 YSX
Diesel generating set YANMAR 4TNV98 – Three-phase synchronous alternator – Water Cooled
POWER RATINGS THREE-PHASE
- Stand-By three-phase power: 38 kVA (30.4 kW) / 400V / 54.8 A
- PRP three-phase power: 35 kVA (28 kW) / 400V / 50.5 A
- Frequency: 50 Hz
POWER RATINGS SINGLE-PHASE
- Stand-By single-phase power: 31 kVA (kW) / 230V – 115V / 134.8 A – 269.6A
- PRP single-phase power: 28 kVA (kW) / 230V – 115V / 121.7 A – 243.5A
- Frequency: 50 Hz
-
Mosa GE 45 YSC
Diesel generating set YANMAR 4TNV98T – Three-phase synchronous alternator – Water Cooled
POWER RATINGS
- Stand-By three-phase power: 44 kVA (35,2 kW) / 400V / 63,5A
- PRP three-phase power: 40 kVA (32 kW) / 400V / 57,7A
- PRP single-phase power: 15.5 kVA / 230V / 67.4 A
- Frequency: 50 Hz
-
Mosa GE 45 YSX
Generator Diesel YANMAR 4TNV98T – Three-phase synchronous alternator – Three-phase power 42 kVA (33.6 kW) – Single-phase power 15.5 kVA – Water Cooled
MOSA model GE 45 YSX is a super silenced diesel generating set. The machine construction incorporates an integral roll bar, central lifting point, forklift pockets and rear canopy section that is hinged to provide full access to the engine for maintenance. The 100 litre fuel tank provides a running time of 13.5 hours. At 1020kg the machine is compact and easily transportable using the optional site tow or a special galvanized skid base frame.
This attention to detail can also be seen in the rounded edges of the canopy designed for rainwater drainage away from the control panel.
The bunded base must ensure the containment of fluids in the engine and fuel tank in the event of any loss, to prevent their dispersion in the environment.
When the Compound System is combined with a double control AVR the Compound System overrides the AVR when a heavy load is applied and also provides a backup voltage regulation in the event of AVR failure.
EAS models are pre-wired to accept the optional MOSA EAS Automatic Start-Up Panel which plugs into the front panel of the Generator and enables the machine to be used as an emergency standby power unit in the event of power failure from the mains supply.
Also available is an optional TCM remote control allowing start/stop of the engine up to 10 metres distance from the machine.
Suitable for a wide range of uses including industrial sites, residential, construction, noise sensitive environments and emergency standby power.
In according with CE regulation
Welding & Gas
Hardware
- Tools & Machinery
- Steel Supplies
- Key Clamps